Complete
beacon management system built into a flasher with 2 external control
and 3 monitoring points. (2on/off +1 analogue )

Technical specification
| Weight |
: |
250 grams |
| Voltage range |
: |
6.0 to 22 volts DC |
| Idle current |
: |
<1 milliamps |
| Efficiency |
: |
>99% @ 20w load |
| Operating temperature |
: |
-40° C to +60° C |
| Output voltage |
: |
4.5 to 18 +/- 2% |
| Output power |
: |
2 to 120 watts at 12v |
Interfaces with bi-filament, PA6 lampchanger and LED lantern range.
Ideal for use with remote IP66 monitoring terminal and Pelangi
Visual Basic programmed custom built displays.
|
The COMMUNICATOR
flasher has been designed and manufactured to interface with satellite
or VHF/UHF monitoring systems.
- Capable of driving any lamp up to 10 amps from an input voltage
range of 6 to 22 volts with lamp regulation 4.5 to 18 volts RMS.
- Re-programmable parameters, capable of driving lamp at any
character.
- Suitable for use with bi-filament or lampchanger. Counts lamp
in service, number of hours burned with 1st and 2nd lamp alarms.
- Monitors low battery with programmable load disconnect set
at 4.5 to 15 volts.
- Built in photocell with programmable light levels. External
cell can also be used.
- Provides on/off control for two additional pieces of equipment
such as fog signal or traffic light array.
- Provides on/off monitoring of two additional devices such
as intruder and fire alarm.
- Provides additional voltage monitoring 0-25 volts for use
with tide gauges or other typical equipment.
- Provides programmable night dimming in conjunction with photocell.
- Provision for optically isolated synchronising
or ripple flashing with programmed delays for each “Buoy Gate”.
- Communicates by RS232 EIA
port at 1200 baud to a radio modem or PC through LEMO connector.
|